Mechanical and Electrical design of pumping station

Quiz Questions:

   
1. Axial-flow impeller, mixed-flow impeller & centrifugal volute ( radial-flow) type are the three classifications of the centrifugal pumps used for flood protection pumping stations.
       
    True
    False
       
2. Pumps are usually classified by their specific speed. And it is denoted by the equation
       
    Eq 5-1
    Eq 5-2
       
3. The impellers of the ___________ pumps have blades shaped like a propeller.
       
   

Axial

   

Mixed

   

Radial

       
4. A special design of the ___________ pump has a non-clog impeller which makes it very useful for pumping sewage.
       
   

Triode

   

Mixed

   

Centrifugal

       
5. The impeller of the ___________ pumps develops head or discharge pressure by a combination of both a lifting action and a centrifugal force.
       
   

Axial

   

Mixed

   

Radial

       
6. NPSH is abbreviated as _____________________.
       
   

Net positive suction head

   

Net position suction head

       
7. Submersible pumps are considered for stations that have pumping requirements with each pump having a capacity less than 6 m3/s (200 cfs).
       
   

True

   

False

       
8. ____________ is defined as the setting of the impeller eye of the pump with respect to the water surface in the suction sump area.
       
   

Suction

   

Surge

   

Submergence

       
9. The discharge system in a pumping station is not to convey the pumped water from the pumps to the receiving body of water..
       
   

True

   

False

       
10. Discharge piping to pump connections is generally made by means of a flexible coupling with harness bolts across the connection
       
   

True

   

False

       
11. Internal combustion engines used for pump drivers are of the diesel or gas-fueled type.
       
   

True

   

False

       
12. Engines more than 450 kW (600 HP) may be equipped with a manual clutch mechanism, which allows the engine to be started and operated without running the pump.
       
   

True

   

False

       
13. Roller gates are used when the gate opening is too large for slide gates.
       
   

True

   

False

       
14. Pumping units with discharges greater than 600 millimeters (24 inches) should be fitted with detectors to determine the temperature of each pump bowl bearing.
       
   

True

   

False

       
15. As a general rule-of-thumb, motors of 150 kW (200 HP) and below are usually most economically operated at 480 volts.
       
   

True

   

False

       
16. ____________________ Motors of either the squirrel-cage induction or synchronous type are the preferred drives for pumps installed in flood-protection pumping stations.
       
   

Constant-speed

   

Variable speed

       
17. What are the basic variables that classify the motor performance type?
       
   

Starting current, voltage, starting torque

   

Starting torque, starting current, Slip

       
18. A programmable controller (PLC) should be considered for usage when the controls or monitoring requirements of the station become complex.
       
   

True

   

False

       
19. Eq 20-1 & Eq 20-2 represents ________________________.
       
   

Output ratings of the equipment motors

   

Output ratings of the equipment heaters

       
20. Rigid galvanized steel conduit is the most commonly used material for raceways and is suitable for all locations where wiring is required within a pumping station.
       
   

True

   

False

       
   
 
 