SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

Quiz Questions:

   
1. A single building enclosing a number of tenants and occupants such as retail stores, drinking and dining establishments, entertainment and amusement facilities, passenger transportation terminals, offices, and other similar uses wherein two or more tenants have a main entrance into one or more malls is called a _______________.
       
    Covered Mall Building
    Anchor Building
       
2. A public seating area located in the mall that serves adjacent food preparation tenant spaces is a ______________.
       
    Food Court
    Gross leasable area
       
3. Figure 402.2 represents _____________________.
       
    Covered Mall Building
    Anchor Building
       
4. The occupant load factor (OLF) is not required to be less than ________ and should not exceed ______.
       
    20, 40
    30, 50
    40, 60
       
5. The minimum width of an exit pas sage way or corridor from a mall is ____________ inches.
       
    66
    77
    55
       
6. The minimum width of the mall should be __________ feet.
       
    10
    20
    30
       
7. Fire resistance rated separation is not required between tenant spaces and the mall.
       
    True
    False
       
8. ______________buildings are defined as buildings with occupied floors located more than 75 feet above the lowest level of fire department vehicle access.
       
    High-rise
    Low-rise
       
9. The thickness of foam plastic signs should not be greater than 1/2 inch (12.7 mm).
       
    True
    False
       
10. Repair garages used for repair of vehicles fueled by non odorized gases, such as hydrogen and non odorized LNG, shall be provided with an approved flammable gas-detection system.
       
    True
    False
       
11. The fly gallery is not an integral part of the stage construction.
       
    True
    False
       
12. A minimum of one exit stair way shall be permitted for airport traffic control towers of any height provided that the occupant load per floor does not exceed 15.
       
    True
    False
       
13. An area of land or water or a structural surface that is used, or intended for use, for the landing and taking off of helicopters, and any appurtenant areas that are used, or intended for use, for _________ facilities.
       
    Heliport
    Helistop
       
14. Gas rooms are used exclusively for the storage or use of hazardous gases in excess of the maximum allowable quantities per control area.
       
    True
    False
       
15. A ___________room is a power-ventilated, fully enclosed room used exclusively for open spraying of flammable and combustible materials.
       
    Spray
    Surface
       
16. Over head heating pipes should have a clearance of not less than _____ inches from combustible contents in the dryer.
       
    One
    Two
    Three
       
17. Storage areas for flammable and combustible liquid tanks inside of structures are located at or above grade and are separated from the processing area by not less than 2-hour fire barriers, which can be termed as a_________.
       
    Tank Storage
    Process Storage
       
18. Section 425 talks in detail about _________________.
       
    Public Lodging Establishments
    Public Food Service Establishments
       
19. Examples of underground buildings are represented in figure ____________.
       
    Figure 405.1
    Figure 405.2
    Figure 405.4
       
20. Ice storage bins are drained through an air gap in accordance with the provisions of the Florida Building Code, Plumbing.
       
    True
    False
       
   
 
 