General Building Heights and Areas
Quiz Questions:
1.
Figure 502.1(1) represents________________.
Building area projected
Basement area
2.
Address numbers shall be Arabic numerals or alphabetical letters.
True
False
3.
A basement shall be considered as a story above grade plane where the finished surface of the floor above the basement is: More than______ feet above grade plane; or more than _________ feet above the finished ground level at any point.
Four, eight
Six, twelve
Five, ten
4.
A reference plane representing the average of finished ground level adjoining the building at exterior walls is termed as a________________.
Building plan
Grade plan
5.
The vertical distance from grade plane to the average height of the highest roof surface is the _______________.
Height of the mall
Height of the building
Height of the food court
6.
MEZZANINE is not an intermediate level or levels between the floor and ceiling of any story.
True
False
7.
Figure 502.1(4) represents __________________________.
Determination of grade plan elevation when grade slopes uniformly along the entire length of the exterior walls
Determination of grade plan where grade slopes away from the exterior
8.
The buildings of type I construction may be of unlimited size based on their type of construction alone.
True
False
9.
The aggregate area of a mezzanine within a room should not exceed ___________of the floor area of that room or space in which they are located.
One-half
One-third
10.
If a mezzanine is closed off from the larger room, an undetected fire could develop such that it would jeopardize or eliminate the opportunity for occupant escape.
True
False
11.
In buildings or spaces that are required to be protected with an automatic fire suppression system, fire suppression above and below the equipment platform is needed so the equipment platform will not obstruct sprinkler coverage or delay sprinkler activation if a fire develops below the platform.
True
False
12.
Equation 5-2 denotes _______________.
Maximum allowable area for each floor
Frontage increase
13.
Figure 506.2 represents ______________.
Maximum allowable area for each floor
Frontage increase
14.
The maximum area of a building with more than one story above grade plane shall be determined by_________ the allow able area of the first story (Aa), as determined in Section 506.1, by the number of stories above grade plane.
Multiplying
Dividing
15.
The height limitation for buildings of Type IIA construction in Group R-2 shall be increased to nine stories and 100 feet where the building is separated by not less than 50 feet from any other building on the lot and from lot lines, the exits are segregated in an area enclosed by a 2-hour fire-resistance-rated fire wall and the first-floor construction has a fire-resistance rating of not less than 11/2 hours.
True